STARTPAGINAMAIL.NL ≡ Sports Glasses Grenade Launchers Academic Tennis
  • Fiber Optic Cables

  • MTP 12 Jumper,Multimode fiber(OM4),Type C,MTP 12 Jumper UPC (Female) to MTP 12 Jumper UPC (Female),OFNP-Plenum,1m (3.28ft)~100m (328.08ft)

MTP 12 Jumper,Multimode fiber(OM4),Type C,MTP 12 Jumper UPC (Female) to MTP 12 Jumper UPC (Female),OFNP-Plenum,1m (3.28ft)~100m (328.08ft)

$54.9 $78.51
Description MTP 12 Jumper MTP® jumpers support smooth upgrades to higher data rates in data centers when used alongside our trunk assemblies. They are primarily applied for patching tasks within network cabinets. MTP® cables serve as a cost-effective substitute for traditional field termination, offering an efficient solution for high-density fiber patching in environments requiring space optimization and simplified cable routing. Because MTP®-12 interfaces also accommodate MTP®-8 configurations, they are highly suitable for 8-fiber multimode optical transceivers, such as 40G QSFP SR4/CSR4 and 100G QSFP28 SR4 module connections. Please note: US Conec’s MTP® connectors meet all MPO standard requirements and deliver patented design innovations, superior alignment accuracy, outstanding durability, and noticeable performance enhancements when compared to typical MPO connectors on the market.   MTP 12 Jumper Advantage Specifications Connector A:US Conec MTP® Elite Female (Pinless) Connector B:US Conec MTP® Elite Female (Pinless) Polish Type:UPC to UPC Fiber Mode:OM4 50/125μm Wavelength:850/1300nm Fiber Count:12 Fibers Polarity:Type C Cable Outside Diameter (OD):3.0mm Cable Jacket:Plenum (OFNP) Min. Bend Radius (Optical Fiber):7.5mm Min. Bend Radius (Fiber Cable):20/10D (Dynamic/Static) Connector Durability:500 times Tensile Strength:80/240N (Long/Short Term) Insertion Loss:0.35dB Max (0.15dB Typ.) Return Loss:≥20dB Attenuation at 850nm:≤2.3dB/km Attenuation at 1300nm:≤0.6dB/km Operating Temperature:-10 to 60°C (14 to 140℉) Storage Temperature:-10 to 70°C (14 to 158℉) *MTP is a registered trademark of US Conec Ltd.   MTP Patch Cable Polarity The mtp 12 jumper Type C connector uses a special polarity method designed for duplex pair reversal. It rearranges the fiber positions so that each pair (Tx/Rx) is crossed to support standard two-fiber transceiver communication. This polarity is commonly used in structured cabling systems with MTP-to-LC cassettes.   mtp 12 jumper Key Features: Connector Type:MTP® (multi-fiber push-on) Fiber Count:12 fibers in one row Polarity Type:Type C / cross pair (pair-wise flip) Connector Orientation:Key-up to key-down Application:Duplex transmission systems (e.g., 10G Ethernet), MTP-LC cassette systems   MTP 12 Jumper Advantage 100% use low-loss connectors Each MPO patch cord is fully tested for insertion loss & return loss, 100% tested, and batch goods are not sloppy Each line guarantees 3D geometric dimensions and end face integrity, imported equipment measures 3D, and dust-free workshops ensure cleanliness Affordable price, quality assurance, source manufacturers take both quality and price into consideration All materials have passed REACH/ROHS environmental protection requirements and are of export quality Adequate inventory, complete materials, and efficient production Customization of special specification MPO patch cords, fast delivery   MTP 12 Jumper SPIN-LEAF connection method MTP 12 Jumper Application High-speed interconnection in data centers It is used for direct connection of 40G/100G optical modules, supports 400G high-speed transmission, and can improve wiring density and transmission efficiency. For example, 400G QSFP-DD DR4 optical modules can be directly connected through MPO/MTP-8 multimode fiber jumpers. High-density wiring scenarios In the backbone wiring of data centers, MTP/MPO trunk fiber jumpers are used in conjunction with adapter modules to achieve interconnection and cross-connection between devices, saving 45% of wiring space. Branch jumpers are used to connect devices with different rates (such as 10G and 40/100G devices). 100G/400G transmission expansion Supports branch connection of 100G QSFP28 optical modules to 4 25G SFP28 optical modules, or interconnection of 100G CFP optical modules to another CFP. Fiber-to-Building Applications It is used for fiber-to-the-building (FTTB) wiring to meet the needs of high-density fiber access.   MTP 12 Jumper Test Series MTP 12 Jumper Polarity Test Process ‌End face cleaning: Use special equipment to remove end face contaminants to avoid affecting the test accuracy. Morphology detection: Analyze the end face microstructure through 3D imaging technology to detect surface roughness, scratches and other defects. Insertion loss test: Measure the contact loss between the fiber end face and the connector ferrule to evaluate the signal transmission quality. Polarity verification: Confirm the correspondence between the number of fiber cores and the connector guide hole to prevent communication failure caused by wrong connection. MTP 12 Jumper Test Key Indicators Cleaning efficiency: It must reach more than 98% to ensure that there are no residual stains on the end face. ‌Detection accuracy: The resolution of 3D morphology detection must be less than 1.5μ, and the insertion loss error must be controlled within 0.3dB. Test time: It takes about 10 seconds to detect a single fiber core of a 12-core MPO jumper, and the overall test takes about 2 minutes. MTP 12 Jumper cable Test Common Problems Pollution sensitivity: Tiny particles on the end face will cause increased loss, and non-contact cleaning methods are required to protect the end face.
Fiber Optic Cables

Fiber Optic Cables

  • MTP 16 Jumper,Multimode fiber(OM4),Type C,MTP 16 Jumper APC (Female) to MTP 16 Jumper APC (Female),OFNP-Plenum,1m (3.28ft)~100m (328.08ft)
    $55.83 $74.81
  • MTP 16 Jumper,Multimode fiber(OM4),Type B,MTP 16 Jumper APC (Male) to MTP 16 Jumper APC (Male),OFNP-Plenum,1m (3.28ft)~100m (328.08ft)
    $63.78 $102.69
  • MTP 24 Jumper,Multimode fiber(OM4),Type B,MTP 24 Jumper UPC (Male) to MTP 24 Jumper UPC (Male),OFNP-Plenum,1m (3.28ft)~100m (328.08ft)
    $52.14 $90.72
  • MTP 12 Jumper,Multimode fiber(OM4),Type B,MTP 12 Jumper UPC (Female) to MTP 12 Jumper UPC (Female),OFNP-Plenum,1m (3.28ft)~100m (328.08ft)
    $47.47 $76.9
  • MTP 24 Jumper,Multimode fiber(OM4),Type A,MTP 24 Jumper UPC (Male) to MTP 24 Jumper UPC (Male),OFNP-Plenum,1m (3.28ft)~100m (328.08ft)
    $66.09 $92.53
  • MTP 24 Jumper,Multimode fiber(OM4),Type B,MTP 24 Jumper UPC (Female) to MTP 24 Jumper UPC (Female),OFNP-Plenum,1m (3.28ft)~100m (328.08ft)
    $64.97 $117.6
  • MTP 12 Jumper,Multimode fiber(OM4),Type C,MTP 12 Jumper UPC (Male) to MTP 12 Jumper UPC (Male),OFNP-Plenum,1m (3.28ft)~100m (328.08ft)
    $58.94 $100.2
  • MTP 16 Jumper,Multimode fiber(OM4),Type A,MTP 16 Jumper APC (Male) to MTP 16 Jumper APC (Male),OFNP-Plenum,1m (3.28ft)~100m (328.08ft)
    $61.68 $84.5
  • MTP 16 Jumper,Multimode fiber(OM4),Type A,MTP 16 Jumper APC (Female) to MTP 16 Jumper APC (Female),OFNP-Plenum,1m (3.28ft)~100m (328.08ft)
    $60.2 $87.29
  • MTP 12 Jumper,Multimode fiber(OM4),Type C,MTP 12 Jumper UPC (Female) to MTP 12 Jumper UPC (Female),OFNP-Plenum,1m (3.28ft)~100m (328.08ft)
    $54.9 $78.51
  • MTP 16 Jumper,Multimode fiber(OM4),Type B,MTP 16 Jumper APC (Female) to MTP 16 Jumper APC (Female),OFNP-Plenum,1m (3.28ft)~100m (328.08ft)
    $47.33 $56.8
  • MTP 24 Jumper,Multimode fiber(OM4),Type A,MTP 24 Jumper UPC (Female) to MTP 24 Jumper UPC (Female),OFNP-Plenum,1m (3.28ft)~100m (328.08ft)
    $37.24 $67.78
  • MTP 24 Jumper,Multimode fiber(OM4),Type C,MTP 24 Jumper UPC (Female) to MTP 24 Jumper UPC (Female),OFNP-Plenum,1m (3.28ft)~100m (328.08ft)
    $44.55 $57.02
  • MTP 24 Jumper,Multimode fiber(OM4),Type C,MTP 24 Jumper UPC (Male) to MTP 24 Jumper UPC (Male),OFNP-Plenum,1m (3.28ft)~100m (328.08ft)
    $47.61 $82.37
  • MTP 12 Jumper,Multimode fiber(OM4),Type B,MTP 12 Jumper UPC (Male) to MTP 12 Jumper UPC (Male),OFNP-Plenum,1m (3.28ft)~100m (328.08ft)
    $60.45 $86.44
  • MTP 16 Jumper,Multimode fiber(OM4),Type C,MTP 16 Jumper APC (Male) to MTP 16 Jumper APC (Male),OFNP-Plenum,1m (3.28ft)~100m (328.08ft)
    $60.59 $92.7

© 2026 - STARTPAGINAMAIL.NL